Page 11
Lead Frequency
(J5 pins 1, 2, 4, 5, 6)
The wiring for the Lead Frequency is determined by the sensor. Figures 5 through 8 illustrate the wiring for the various
sensors. For signal level and performance specifications, refer to Appendices: Appendix A .
*Total currant draw from the +12V_Aux (J5-Pin 1) should not
exceed 150 Milliamps.
Figure 5 Lead Frequency
Quadrature Differential Sensor (Bidirectional)
Figure 6 Lead Frequency
Quadrature Single-Ended Sensor (Bidirectional)
+12V Pwr
A
A
B
B
Common
1
2
3
4
5
6
J5
*
+12V_Aux
A
A
B
B
Com
Total currant draw from the +12V_Aux (J5-Pin 1) should not
exceed 150 Milliamps.
+12V Pwr
A
B
Common
1
2
3
4
5
6
J5
*
+12V_Aux
A
A
B
B
Com